Medical Container

Infection-Control Negative Pressure Container! Safe and Secure! Helps Prevent Healthcare-Associated Infections!

The unit is built to comply with Japan’s stringent building confirmation requirements, reflecting the country’s high seismic-safety standards, ensuring safe use in any country.

Features

“We want to build a fever clinic, consultation rooms, and laboratory in a location isolated from the main building to eliminate the risk of secondary infection!”

“We want to quickly add consultation and examination rooms as part of our virus-control measures!”

“We want to use the consultation and examination rooms not only for the short term, but also over the long term!”

 

The Infection-Control Negative Pressure Container is designed to meet these needs.

 

  • Easy installation, anytime and anywhere

The container can be transported by truck and installed easily.
Note) Installation may not be possible depending on transportation conditions.

  • Suitable for both short-term and long-term use

It can be installed for long-term use as a building structure.
Note) The unit is built to comply with Japan’s stringent building confirmation requirements, reflecting the country’s high seismic-safety standards, ensuring safe use in any country.

  • Reliable infection control for peace of mind

A negative-pressure unit compliant with CDC guidelines is provided as standard equipment.

  • Built to withstand various environments

Its robust container construction withstands heavy-snow areas, salt-damage-prone coastal areas, and other demanding environments.

  • Comfortable use throughout the year

The interior walls feature an insulated structure, ensuring a comfortable environment all year round.
Air conditioning is provided as standard equipment.

  • Maintains negative pressure inside

The container maintains a negative-pressure environment inside the consultation and examination rooms.
A negative-pressure unit is provided as standard equipment.

  • Designed to reduce infection risk for healthcare workers

The airflow design takes both air supply and exhaust into consideration to help reduce the infection risk for healthcare workers.

 

Options

  • Desk, chairs, and examination table inside the consultation/examination room

  • Hospital signage

  • Salt-damage and heavy-snow resistance

  • Floor drainage function

 

Available at Additional Cost

  • Building confirmation application services in Japan

  • Unloading and installation work at the site

  • Custom design

  • Foundation work

Specifications

Container Body Comply with Japan’s stringent building confirmation requirements Negative pressure generator

HEPA-filtered Air Exhaust Unit: NEU-10

Outer dimensions (mm)

6,058 × 2,438 × 2,896 20ft size Air conditioner Wall-mounted air conditioner     for approximately 13.2㎡
Insulated  Non-combustible insulation panels LIghting LED × 3
Door Entrance/Exit door × 2,    Interior sliding door × 1 Outlet Duplex outlets × 2
Window 1 Distribution Board 1
Wall Panel
Ceiling Panel