This is an energy-saving model of a standard closed-type plant growth chamber, equipped with dimmable LEDs as standard.
You can choose the lighting from the following:
-White color: sun-like LED (SUNRAY LIGHT)
-Yellow/Pink color: LED for plant growth (PLANTFLEC)
Environmental control can be adjusted to meet research needs, such as short-day and long-day treatments. There are two types of control system: Changeover between constant operation and day/night switching operation or Program control. Three-position controller is used for temperature and humidity control, which provides low running costs. You can choose between the 240L and 410L sizes.

Features

  • An operation touch panel with time display is mounted on the upper part of the main body, which allows easy operation.
  • Type -S: constant operation at any temperature/light/ (humidity) and day/night switching operation.
  • Type -SP: program control (real-time mode / accumulated operation time mode).
  • 5-side irradiation with continuous dimming from 0% or 20% to 100%.
  • Type LH does not require a drainage system due to its built-in forced evaporation system.
  • Three-position controller is used for temperature and humidity control (proportional control for heating), which provides low running costs.
  • The inner door has energy-saving functions, being used as one door or two up-and-down doors as per usual.
  • Two-level wind speed control is installed to protect wind-sensitive plants.
  • A hole of 40 mm diameter for measurement is included as standard.
  • Humidity control system can be selected from “only humidification” or “only dehumidification” or “both humidification and dehumidification.”

LED spectrum

Applications

  • Plant cell/tissue culture, germination, acclimation, or growth test
  • Environmental test
  • Growth of rice, arabidopsis, etc.
  • Insect experiment
  • Environmental resistance test for plants
  • Storage test at constant temperature and at constant humidity.

Options

  • Table for a water tank (for LPH) (Size:W300×D400×H900mm)
  • Evaporator for drained water (for LPH)

Specifications

240 ℓ series   

* S:White LED (SUNRAY LIGHT), D: Yellow LED (PLANTFLEC), P: Pink LED (PLANTFLEC) 

Model White LED LH-241PFST-S LPH-241PFST-S LH-241PFST-SP LPH-241PFST-SP
Yellow LED LH-241PFDT-S LPH-241PFDT-S LH-241PFDT-SP  LPH-241PFDT-SP 
Pink LED LH-241PFPT-S LPH-241PFPT-S LH-241PFPT-SP LPH-241PFPT-SP
Outer dimensions (mm) W760 × D726 × H1,767
Inner dimensions (mm) W512 × D485 × H980 
Control system

Changeover between constant operation
and day/night switching operation 

Real-time based control (24 hours)/Cumulated hours-based control(Up to 999 hours and 59 minutes/step)

24steps/5patterns with a pattern link function

Repeat 1 to 99 times or unlimited
 Control methods Three-position control method: Refrigerator and humidifier, ON/OFF control; heater, proportional control 
Temperature  +5℃ to 50℃ ± 1℃ (+15℃ ~ when all lights on)
Humidity

50-80%RH ± 10%RH
(15-45℃)

50-80%RH ± 10%RH
(15-45℃)

Illuminance White and Yellow: 0 to 20,000 lx,        Pink: 0 to 12,000 lx 
They can be continuously dimmed from 20% to 100% or 0% (all lights off)
Photon flux density

White:0 to  330 μmolm-2s-1,      Yellow0 to 280 μmolm-2s-1,       Pink0 to 260 μmolm-2s-1 

Light

source

Illumination

White: Straight tube sun-like LED lamp (SUNRAY LIGHT) 
Yellow and Pink: Straight tube LED lamp (PLANTFLEC) for plant growth

Number of lamps Left, right, and rear: 4 lamps (40W) x 3 sides, Ceiling and door: 4 lamps (20W) x 2 sides
Refrigerator 300W 
Heater  400W 500W 400W 500W
Humidifier 80W  80W 
Shelf 5 shelves (adjustable)  

Operation current

(maximum)

White: 9A
Yellow and Pink: 8A

White: 13A
Yellow and Pink: 12.5A

White: 9A
Yellow and Pink: 8A

White: 13A
Yellow and Pink: 12.5A

Power requirement Single phase 100V 50/60Hz 15A E 
Weight (kg) About 225 About 235 About 225 About 235

410 ℓ series

Model White LED LH-411PFST-S LPH-411PFST-S LH-411PFST-SP LPH-411PFST-SP
Yellow LED LH-411PFDT-S LPH-411PFDT-S LH-411PFDT-SP  LPH-411PFDT-SP 
Pink LED LH-411PFPT-S LPH-411PFPT-S LH-411PFPT-SP LPH-411PFPT-SP
Outer dimensions (mm) W880 × D806 × H1,875
Inner dimensions (mm) W670 × D565 × H1,100
Control system

Changeover between constant operation
and day/night switching operation 

Real-time based control (24 hours)/Cumulated hours-based control(Up to 999 hours and 59 minutes/step)

24steps/5patterns with a pattern link function

Repeat 1 ~ 99 times or unlimited
 Control methods Three-position control method: Refrigerator and humidifier, ON/OFF control; heater, proportional control 
Temperature  +5~50℃ ± 1℃ (+15~ when all lights on)
Humidity

50-90%RH ± 10%RH
(15-45℃)*

50-90%RH ± 10%RH
(15-45℃)*

Illuminance White and Yellow: 0 to 20,000 lx,     Pink: 0 to 12,000 lx 
They can be continuously dimmed from 20% to 100% or 0% (all lights off)
Photon flux density White:0 to  330 μmolm-2s-1,      Yellow0 to 280 μmolm-2s-1,      Pink0 to 260 μmolm-2s-1 

Light

source

Light source

White: Straight tube sun-like LED lamp (SUNRAY LIGHT) 
Yellow and Pink: Straight tube LED lamp (PLANTFLEC) for plant growth

Number of lamps  Left, right, rear and door: 4 lamps (40W) x 4 sides, Ceiling: 6 lamps (20W) x 1 side
Refrigerator 300W 
Heater 500W
Humidifier 80W  80W 
Shelf 6 shelves (adjustable)  

Operation current
(maximum)

White: 11A
Yellow and Pink: 10A

White: 14.5A
Yellow and Pink: 13.5A

White: 11A
Yellow and Pink: 10A

White: 14.5A
Yellow and Pink: 13.5A

Power requirement Single phase 100V  50/60Hz 15A E 
Weight (kg) About 275 About 285 About 275 About 285

All types are capable of continuous dimming.

* Temperature sensor: platinum resistance temperature sensor, humidity sensor: polymer film capacitive sensor, humidifier: ultrasonic humidifier.
* The internal outlet of LPH-411PFST-S and LPH-411PFST-SP can be used up to 0.5A, while all other outlets can be used up to 1A.
* These chambers are designed to operate in ambient temperatures 15 to 30℃ in general. The specified performance may not be achieved depending on actual usage conditions.
* Supply purified water (disilled or reverse osmosis water) only.
* The specified performance may not be achieved depending on the combination of temperature and humidity.
* Depending on the sample, drainage installation may be required.

* When lighting, temperature setting should be 15℃ or higher.
* Keep 30cm or more clearance at both sides and the back of the product to prevent exhausted heat from being trapped and hindering the cooling function.
* The specified control accuracy for temperature and humidity applies when lights off.
* For long-term operation under conditions of high temperature and high humidity, please contact us for confirmation.